17.3.11

SAP Note 25097 - Inc. characteristic values in control recipes

Symptom:

Process instruction characteristics can sometimes have incorrect values in process instructions and process messages. For the characteristic PPPI_PHASE_STATUS, for example, the value '00001' should be processd in the control recipe, but instead the language-specific description 'Gestarted' (logon language German) or 'Started' (logon language English) is processed. This incorrect characteristic value causes errors when processing the control recipe in the process control system or for process messages.

Cause and prerequisites

The error is caused when valuating in the master recipe. The language-independent internal characteristic value is not internally processed.

Solution
In a temporary solution for Release 3.00 (FCS), the internal values are processed in the master recipe. This does not apply to the process order which displays the language-specific description in the user interface but processes the correct internal value internally. This solution will also be available for the master recipe as of Release 3.0A.
The correction can be picked up from sapserv3 (internal transfer order P30K000750). It can be found in the directory /dist/permanent/Note.0025097. Note 13719 describes how to import a correction from sapserv3 into the customer system.
Caution: This correction can only be used by FCS customers and may no longer be used as of Release 3.0A! !! !

Additional key words

Process instruction characteristics

No comments: