SAP Note 28541 - SM31 table maintenance routine after an upgrade to 30A

Symptom:

The SM31 table maintenance routine does not function properly after an upgrade to 3.0. The message TB056 'Please generate maintenance interface for tables' appears.

Cause and prerequisites

The old table maintenance routine is used.

Solution
You can display the contents of tables for 3.0 as follows:
a) Go to the dictionary maintenance routine (SE11), enter the table names, and choose 'Display'. In the next screen, choose 'Utilities -> Table contents'. A selection menu appears in which you can formulate restrictive conditions. Press the 'Execute' pushbutton. The table entries are now listed.
b) Call transaction SE16 (Data Browser). Enter the table names and choose 'Execute'. Further handling is as described above.
Proceed as follows if you want to create entries:
a) With SE11, go to the table display routine and choose 'Utilities -> Create entries'. Enter the entries in the following interactive window.
b) Call transaction SE16, enter the table names and press the pushbutton 'Create entries'. You can then enter the table entries in the following interactive window.

Additional key words

SM31, table maintenance, maintenance interface, TB056

No comments: