RIWO00-SELEC(02) on SCREEN SAPMIWO0 ( 3400 / 4000 / 3000 / 1000 )
not available.
FM: S 00349 S00349 field RIWO00-SELE screen SAPMIWO0 nnnn
1. The window size you are working with is smaller than the standard size of 25 lines.
2. Variable step loops larger than 25 lines not capable of batch input.
Compression within border has too much space.
Refers to Release 3.0A-3.0C
1. Enlarge your window by at least 25 lines. If this is not possible,
use the second solution.
2. Another method is to change the loop from variable to fixed. This
ensures that two loop lines are always available for batch input.
For this, start Transaction SE52 for program SAPMIWO0 and the
corresponding screen. Confirm function key 'LOOP' and afterwards
'Fixed Loop'. After this, save and generate the screen.
3.) Special procedure for 3.0A-3.0C, if the batch input for a window
with 25 lines does not work.
SAPMIWO0 3400 / 4000 must be zoomed out.
Transaction: SE51
Program: SAPMIWO0
Screen: 3400/4000/3000
You must gain an additional 2 lines. You can check this by the number of lines occupied in the screen attributes.
Delete the outer border. You can also delete blank lines. The step loop must not be within a border.
*--------------------------------------------------------------------*
The result should resemble the diagram below.
Go to the screen attributes. Check the number of lines occupied.
Lines/columns occupied 24 83 <------ Important
maintenance 26 83
EXAMPLE: Screen 3400 of SAPMIWo0
Additional key words
IBIP, batch input, IQS1, IQS2, S00349, SAPMIWO0, IW15, QM04