- 1. A reference operation set is entered during order creation (Transaction CO01). However, this reference operation set is not exploded and taken over into the order. The system generates an order operation.
- 2. Inserting a reference operation set manually into a production order does not work.
- 3. A reference operation set to be inserted via a trigger point is not transferred to the production order.
This is caused by missing Customizing settings.
SolutionAdd the specifications of the reference operation set to the table for controlling the 'Automatic Selection' in shop floor control Customizing (menu path: Operations -> Routing selection -> Automatic selection (Transaction OPJF)) to allow the transfer of reference operation sets.
The entries must be made for the selection ID of the used order type.
Additional key words
C0 807
No comments: