When displaying a report group, the authorization is checked for activity '3 ' and not for activity '03'.
The same error occurs in mass generator RGRJBG00 and in program RGRPTT00 (display of pointer tables of a report group).
Key words: Report Writer, authorization, authorization check, authorization object G_803J_GJB, transaction GR55.
Program error.
SolutionPreliminary correction:
Please correct the lines marked "H22860 below in the following programs and Includes:
Include FGRWETOP:
DATA: BEGIN OF ACTIVITY,
* DISPLAY LIKE TACT-ACTVT VALUE 03, "H22860
DISPLAY LIKE TACT-ACTVT VALUE '03', "H22860
END OF ACTIVITY.
Program RGRJBG00:
DATA: BEGIN OF ACTIVITY,* DISPLAY LIKE TACT-ACTVT VALUE 03, "H22860
DISPLAY LIKE TACT-ACTVT VALUE '03', "H22860
END OF ACTIVITY.
Program RGRPTT00:
DATA: BEGIN OF ACTIVITY,* DISPLAY LIKE TACT-ACTVT VALUE 03, "H22860
DISPLAY LIKE TACT-ACTVT VALUE '03', "H22860
END OF ACTIVITY.